| 1.1 |
Date updated: |
May 24, 2013 |
| 1.2 |
Vessel's name: |
Genmar Horn |
| 1.3 |
IMO number: |
9173757 |
| 1.4 |
Vessel's previous name(s) and date(s) of change: |
CRUDE HORN (Mar 17, 2004) NORD HORN (Oct 04, 2000) |
| 1.5 |
Date delivered: |
Jun 03, 1999 |
| 1.6 |
Builder (where built): |
DAEWOO KOREA |
| 1.7 |
Flag: |
Marshall Island |
| 1.8 |
Port of Registry: |
MAJURO |
| 1.9 |
Call sign: |
V7BG3 |
| 1.10 |
Vessel's satcom phone number: |
INMST F -764673881/2 > INMST M - 763621632 |
| Vessel's fax number: |
INMST F - 764673883 > INMST M - 763621633 |
| Vessel's telex number: |
INMST C-453832186 |
| Vessel's email address: |
ghorn@gmmport.pt |
| 1.11 |
Type of vessel: |
Oil Tanker |
| 1.12 |
Type of hull: |
Double Hull |
| 1.13 |
Classification society: |
Det Norske Veritas |
| 1.14 |
Class notation: |
+1A1 TANKER FOR OIL, ESP,OPP-F, E0, LCS-SID, VCS-2B, CSA-1(25), ICM(BTs) |
| 1.15 |
If Classification society changed, name of previous society: |
Det Norske Veritas |
| 1.16 |
If Classification society changed, date of change: |
Not Applicable |
| 1.17 |
IMO type, if applicable: |
N/A |
| 1.18 |
Does the vessel have ice class? If yes, state what level: |
No , N/A |
| 1.19 |
Date / place of last dry-dock: |
Jun 18, 2009 |
Setubal, Portugal |
| 1.20 |
Date next dry dock due |
Jun 30, 2014 |
| 1.21 |
Date of last special survey / next survey due: |
Jun 18, 2009 |
Mar 31, 2014 |
| 1.22 |
Date of last annual survey: |
May 19, 2012 |
| 1.23 |
If ship has Condition Assessment Program (CAP), what is the latest overall rating: |
(Not Applicable) |
| 1.24 |
Does the vessel have a statement of compliance issued under the provisions of the Condition Assessment Scheme (CAS): If yes, what is the expiry date? |
N/A |
| 1.25 |
Length Over All (LOA): |
274 m |
| 1.26 |
Length Between Perpendiculars (LBP): |
264 m |
| 1.27 |
Extreme breadth (Beam): |
48 m |
| 1.28 |
Moulded depth: |
23.2 m |
| 1.29 |
Keel to Masthead (KTM) / KTM in collapsed condition (if applicable): |
49.6 m |
0 m (Not applicable) |
| 1.30 |
Bow to Center Manifold (BCM) / Stern to Center Manifold (SCM): |
134 m |
140 m |
| 1.31 |
Distance bridge front to center of manifold: |
94.2 m |
| 1.32 |
Parallel body distances: |
Lightship |
Normal Ballast |
Summer Dwt |
| Forward to mid-point manifold: |
59 m |
68.5 m |
68.5 m |
| Aft to mid-point manifold: |
37 m |
55 m |
70.2 m |
| Parallel body length: |
96 m |
123.5 m |
138.7 m |
| 1.33 |
FWA at summer draft / TPC immersion at summer draft: |
388 mm |
117.5 MT |
| 1.34 |
What is the max height of mast above waterline (air draft) |
Full Mast |
Collapsed Mast |
| Lightship: |
47.137 m |
0 m |
| Normal ballast: |
41.85 m |
0 m |
| At loaded summer deadweight: |
32.578 m |
0 m |
| 1.35 |
Net Tonnage: |
50672 |
| 1.36 |
Gross Tonnage / Reduced Gross Tonnage (if applicable): |
81526 |
64702 |
| 1.37 |
Suez Canal Tonnage - Gross (SCGT) / Net (SCNT): |
81191.87 |
72968.16 |
| 1.38 |
Panama Canal Net Tonnage (PCNT): |
|
| 1.39 |
Loadline |
Freeboard |
Draft |
Deadweight |
Displacement |
| Summer: |
5.221 m |
17.022 m |
159475 MT |
182370 MT |
| Winter: |
5.575 m |
16.668 m |
155317 MT |
178212 MT |
| Tropical: |
4.867 m |
17.376 m |
163633 MT |
186528 MT |
| Lightship: |
19.78 m |
2.463 m |
|
22895 MT |
| Normal Ballast Condition: |
14.493 m |
7.75 m |
55119 MT |
78014 MT |
| 1.40 |
Does vessel have multiple SDWT? |
Yes |
| 1.41 |
If yes, what is the maximum assigned deadweight? |
159475 MT |
| 1.42 |
Registered owner - Full style: |
GMR HORN LLC Trust Company Complex-Ajeltake Road-Ajeltake
Island- Majuro MH96960- Marshall Island c/o
General Maritime Management LLC, 299,Park
Avenue, 2nd Floor, New York, N.Y. 10171 Tel: +1 (212) 763-5600 Fax: +1 (212) 763-5604 Telex: +23 6737564 Email: operations@gmmllc.us Web: www.generalmaritimecorp.com Company IMO#: 5026519 |
| 1.43 |
Technical operator - Full style: |
General Maritime Management (Portugal), Lda Largo Rafael Bordalo,Pinheiro, 20 - 3rd Floor,1200
-369 Lisboa - Portugal Tel: +351 (21) 322 0240 Fax: +351 (21) 342 2754 Telex: Not Applicable Email: operations@gmmport.pt Web: www.generalmaritimecorp.com Company IMO#: 1454108 |
| 1.44 |
Commercial operator - Full style: |
Unique Tankers LLCc/o Unipec UK Co Ltd Lawn House74 Shepherds Bush Green - London /
W12 8QE Tel: +44 208 811 8588 Fax: +44 208 811 8589 Telex: Not Applicable Email: fleetops@unipec.co.uk Web: WWW.GENERALMARITIMECORP.COM |
| 1.45 |
Disponent owner - Full style: |
Unique Tankers LLC
c/o Unipec UK Company Ltd Lawn House
74 Shepherds Bush Green
London
W12 8QE Tel: +44 (208) 811 8534 Email: fleetops@unipec.co.uk |
| |
| 2.1 |
Safety Equipment Certificate: |
Jul 24, 2009 |
May 19, 2012 |
Jun 30, 2014 |
| 2.2 |
Safety Radio Certificate: |
Jul 16, 2009 |
May 19, 2012 |
Jun 30, 2014 |
| 2.3 |
Safety Construction Certificate: |
Jul 24, 2009 |
May 19, 2012 |
Jun 30, 2014 |
| 2.4 |
Loadline Certificate: |
Jul 16, 2009 |
May 19, 2012 |
Jun 30, 2014 |
| 2.5 |
International Oil Pollution Prevention Certificate (IOPPC): |
May 11, 2011 |
May 19, 2012 |
Jun 30, 2014 |
| 2.6 |
Safety Management Certificate (SMC): |
Aug 05, 2009 |
Jan 07, 2012 |
Apr 21, 2014 |
| 2.7 |
Document of Compliance (DOC): |
Nov 23, 2010 |
Feb 05, 2013 |
Nov 28, 2015 |
| 2.8 |
USCG (specify: COC, LOC or COI): COC |
May 19, 2012 |
May 19, 2012 |
May 19, 2014 |
| 2.9 |
Civil Liability Convention Certificate (CLC): |
Jan 30, 2013 |
|
Feb 20, 2014 |
| 2.10 |
Civil Liability for Bunker Oil Pollution Damage Convention Certificate (CLBC): |
Feb 20, 2013 |
|
Feb 20, 2014 |
| 2.11 |
U.S. Certificate of Financial Responsibility (COFR): |
Mar 15, 2012 |
|
Mar 15, 2015 |
| 2.12 |
Certificate of Fitness (Chemicals): |
Not Applicable |
Not Applicable |
Not Applicable |
| 2.13 |
Certificate of Fitness (Gas): |
Not Applicable |
Not Applicable |
Not Applicable |
| 2.14 |
Certificate of Class: |
Jul 10, 2009 |
May 19, 2012 |
Jun 30, 2014 |
| 2.15 |
International Ship Security Certificate (ISSC): |
Apr 21, 2009 |
Not Applicable |
Apr 21, 2014 |
| 2.16 |
International Sewage Pollution Prevention Certificate (ISPPC) |
Jul 15, 2009 |
|
Jun 30, 2014 |
| 2.17 |
International Air Pollution Prevention Certificate (IAPP): |
Jul 15, 2009 |
May 19, 2012 |
Jun 30, 2014 |
| 2.18 |
Does vessel have all updated publications as listed in the Vessel Inspection Questionnaire, Chapter 2- Question 2.24, as applicable: |
Yes |
| 2.19 |
Owner warrant that vessel is member of ITOPF and will remain so for the entire duration of this voyage/contract: |
Yes |
| |
| 3.1 |
Nationality of Master: |
Portuguese |
| 3.2 |
Nationality of Officers: |
Portuguese, Russian, Indian, Croatian, Filipino, Romanian |
| 3.3 |
Nationality of Crew: |
Filipino, Portuguese |
| 3.4 |
If Officers/Crew employed by a Manning Agency - Full style: |
Officers: GMM Portugal - Crew Dept + General Maritime Crewing Pte Ltd Largo Rafael Bordalo Pinheiro, 20-3rd Floor 1200-369 Lisboa - Portugal Tel: +351 21 322 0240 Fax: +351 21 342 2754 Telex: Not Applicable Email: crew@gmmport.pt Crew: GMM Portugal - Crew Dept + General Maritime Crewing Pte Ltd 78 Shenton Way.,#12-03/04,Singapore 079120 Tel: +65 6323 2503 Fax: +65 6323 2766 Telex: Not Applicable Email: gmc.singapore@genmarcrew.com |
| 3.5 |
What is the common working language onboard: |
ENGLISH |
| 3.6 |
Do officers speak and understand English: |
Yes |
| 3.7 |
In case of Flag Of Convenience, is the ITF Special Agreement on board: |
Yes |
| |
| 4.1 |
Can the ship comply with the ICS Helicopter Guidelines: |
Yes |
| 4.2 |
If Yes, state whether winching or landing area provided: |
Landing |
| |
| 5.1 |
Has the vessel Operator submitted a Vessel Spill Response Plan to the US Coast Guard which has been approved by official USCG letter: |
Yes |
| 5.2 |
Qualified individual (QI) - Full style: |
QI, QUALIFIED INDIVIDUAL. MR. JOHN J. GALLAGHER
QUALIFIED INDIVIDUAL SERVICES, INC.
200 Century Parkway, Suite D,
Mount Laurel, New Jersey 08054 EMERGENCY PHONE: +1 703 683 4700 (24 HRS)ALT : +1 215 492 5473 Tel: +1 856 642 2091 Fax: +1 856 642 3945 Email: info@chgms.com |
| 5.3 |
Oil Spill Response Organization (OSRO) -Full style: |
National Response Corporation 3500 Sunrise Highway, suite T103 Great River NY 11739
Main Phone: +1 631 224 9141
Alt. Phone: +1 800 899 4672
Fax: +1 631 224 9082
IOC Fax: +1 631 224 9086
Telex: 49617380 Tel: +1 631 224 9141 Fax: +1 631 224 9082 Telex: 49617380 Web: N/A |
| 5.4 |
Has technical operator signed the SCIA / C-TPAT agreement with US customs concerning drug smuggling: |
Yes |
| |
| 6.1 |
Is vessel fitted with centerline bulkhead in all cargo tanks: |
Yes |
| 6.2 |
If Yes, is bulkhead solid or perforated: |
Solid |
| 6.3 |
Capacity (98%) of each natural segregation with double valve (specify tanks): |
Seg#1: 52843 m3 (1W, 4W, SLOP(S)) Seg#2: 59088 m3 (2W, 5W) Seg#3: 57949 m3 (3W, 6W, SLOP(P)) |
| 6.4 |
Total cubic capacity (98%, excluding slop tanks): |
166683.5 m3 |
| 6.5 |
Slop tank(s) capacity (98%): |
3197 m3 |
| 6.6 |
Residual/Retention oil tank(s) capacity (98%), if applicable: |
0 m3 |
| 6.7 |
Does vessel have Segregated Ballast Tanks (SBT) or Clean Ballast Tanks (CBT): |
SBT |
| 6.8 |
What is total capacity of SBT? |
54554.8 m3 |
| 6.9 |
What percentage of SDWT can vessel maintain with SBT only: |
36.37 % |
| 6.10 |
Does vessel meet the requirements of MARPOL Annex I Reg 18.2: (previously Reg 13.2) |
Yes |
| 6.11 |
How many grades/products can vessel load/discharge with double valve segregation: |
3 |
| 6.12 |
Maximum loading rate for homogenous cargo per manifold connection: |
3300 m3/hr |
| 6.13 |
Maximum loading rate for homogenous cargo loaded simultaneously through all manifolds: |
14400 m3/hr |
| 6.14 |
Are there any cargo tank filling restrictions. If yes, please specify: |
No N/A |
| 6.15 |
Pumps: |
No. |
Type |
Capacity |
| Cargo: |
3 |
Centrifugal |
3500 M3/HR |
| Stripping: |
1 |
Reciprocating |
350 m3/hr |
| Eductors: |
1 |
Other |
450 m3/hr |
| Ballast: |
2 |
Centrifugal |
2000 m3/hr |
| 6.16 |
How many cargo pumps can be run simultaneously at full capacity: |
All (3) |
| 6.17 |
Is ship fitted with a Cargo Control Room (CCR): |
Yes |
| 6.18 |
Can tank innage / ullage be read from the CCR: |
Yes |
| 6.19 |
Can ship operate under closed conditions in accordance with ISGOTT: |
Yes |
| 6.20 |
What type of fixed closed tank gauging system is fitted: |
Radar |
| 6.21 |
Are overfill (high-high) alarms fitted? If Yes, indicate whether to all tanks or partial: |
All |
| 6.22 |
Is a vapor return system (VRS) fitted: |
Yes |
| 6.23 |
Number/size of VRS manifolds (per side): |
2 |
400 mm |
| 6.24 |
State what type of venting system is fitted: |
Individual PV v/v with common line Mast Riser |
| 6.25 |
Does vessel comply with the latest edition of the OCIMF 'Recommendations for Oil Tanker Manifolds and Associated Equipment': |
Yes |
| 6.26 |
What is the number of cargo connections per side: |
3 |
| 6.27 |
What is the size of cargo connections: |
400 mm |
| 6.28 |
What is the material of the manifold: |
STEEL |
| 6.29 |
Distance between cargo manifold centers: |
2500 mm |
| 6.30 |
Distance ships rail to manifold: |
4600 mm |
| 6.31 |
Distance manifold to ships side: |
4600 mm |
| 6.32 |
Top of rail to center of manifold: |
700 mm |
| 6.33 |
Distance main deck to center of manifold: |
2100 mm |
| 6.34 |
Manifold height above the waterline in normal ballast / at SDWT condition: |
17.8 m |
8.321 m |
| 6.35 |
Number / size reducers: |
6 x 550/400mm (22/16") 3 x 550/300mm (22/12") 3 x 550/250mm (22/10") 3 x 550/200mm (22/8") 2 x 550/150mm (22/6") |
| 6.36 |
Is vessel fitted with a stern manifold: |
No |
| 6.37 |
If stern manifold fitted, state size: |
0 mm |
| 6.38 |
Type of cargo heating system? |
COILS |
| 6.39 |
If fitted, are all tanks coiled? |
Yes |
| 6.40 |
If fitted, what is the material of the heating coils: |
Mild steel |
| 6.41 |
Maximum temperature cargo can be loaded/maintained: |
65.9 °C / 150.6 °F |
65.9 °C / 150.62 °F |
| 6.42 |
Are cargo, ballast and slop tanks coated? |
Coated |
Type |
To What Extent |
| Cargo tanks: |
Yes |
COAL TAR EPOXY |
ONE METER FROM TOP AND ONE MTR FORM BOTTOM |
| Ballast tanks: |
Yes |
Tar Epoxy |
Whole Tank |
| Slop tanks: |
Yes |
TAR EPOXY |
Whole Tank |
| 6.43 |
If fitted, what type of anodes are used: |
ZINC |
| |
| 7.1 |
Is an Inert Gas System (IGS) fitted: |
Yes |
| 7.2 |
Is IGS supplied by flue gas, inert gas (IG) generator and/or nitrogen: |
Flue Gas |
| 7.3 |
Is a Crude Oil Washing (COW) installation fitted: |
Yes |
| |
| 8.1 |
Mooring wires (on drums) |
No. |
Diameter |
Material |
Length |
Breaking Strength |
| Forecastle: |
4 |
36 mm |
GALV. STEEL |
275 m |
83 MT |
| Main deck fwd: |
4 |
36 mm |
GALV. STEEL |
275 m |
83.7 MT |
| Main deck aft: |
2 |
36 mm |
GALV. STEELl |
275 m |
83 MT |
| Poop deck: |
6 |
36 mm |
GALV. STEEL |
275 m |
92 MT |
| 8.2 |
Wire tails |
No. |
Diameter |
Material |
Length |
Breaking Strength |
| Forecastle: |
4 |
80 mm |
NYLON |
11 m |
115 MT |
| Main deck fwd: |
4 |
80 mm |
NYLON |
11 m |
115 MT |
| Main deck aft: |
2 |
80 mm |
NYLON |
11 m |
115 MT |
| Poop deck: |
6 |
80 mm |
NYLON |
11 m |
126 MT |
| 8.3 |
Mooring ropes (on drums) |
No. |
Diameter |
Material |
Length |
Breaking Strength |
| Forecastle: |
0 |
0 mm |
|
0 m |
0 MT |
| Main deck fwd: |
0 |
0 mm |
|
0 m |
0 MT |
| Main deck aft: |
0 |
0 mm |
|
0 m |
0 MT |
| Poop deck: |
0 |
0 mm |
|
0 m |
0 MT |
| 8.4 |
Other mooring lines |
No. |
Diameter |
Material |
Length |
Breaking Strength |
| Forecastle: |
2 |
80 mm |
Superflex |
220 m |
114 MT |
| Main deck fwd: |
0 |
0 mm |
0 |
0 m |
0 MT |
| Main deck aft: |
0 |
0 mm |
0 |
0 m |
0 MT |
| Poop deck: |
6 |
80 mm |
Polysteel + Nikasteel |
220 m |
110 MT |
| 8.5 |
Mooring winches |
No. |
# Drums |
Brake Capacity |
| Forecastle: |
2 |
Double Drums |
50.2 MT |
| Main deck fwd: |
2 |
Double Drums |
50.2 MT |
| Main deck aft: |
1 |
Double Drums |
50.20 MT |
| Poop deck: |
3 |
Double Drums |
50.2 MT |
| 8.6 |
Mooring bitts |
No. |
SWL |
| Forecastle: |
4 |
70 MT |
| Main deck fwd: |
5 |
70 MT ((3 sets of 70T + 2 sets of 100 T)) |
| Main deck aft: |
5 |
70 MT |
| Poop deck: |
7 |
70 MT ((7 sets + 1 single) 7 sets – 70T / 1-200T) |
| 8.7 |
Closed chocks and/or fairleads of enclosed type |
No. |
SWL |
| Forecastle: |
6 |
83 MT (6 of 83 T and 2 of 200 T) |
| Main deck fwd: |
9 |
100 MT ((7 -83 T / 2- 100T)) |
| Main deck aft: |
11 |
83 MT |
| Poop deck: |
17 |
83 MT (14 – 83 T / 2 – 100T / 1-200T) |
| 8.8 |
Type / SWL of Emergency Towing system forward: |
ETS 4000 F |
200 MT |
| 8.9 |
Type / SWL of Emergency Towing system aft: |
SAE JIN ETS 4000 A |
200 MT |
| 8.10 |
Number of shackles on port cable: |
13 |
| 8.11 |
Number of shackles on starboard cable: |
14 |
| 8.12 |
What is SWL and size of closed chock and/or fairleads of enclosed type on stern: |
200 MT |
600 x 450 mm |
| 8.13 |
What is SWL of bollard on poopdeck suitable for escort tug: |
200 MT |
| 8.14 |
What is brake horse power of bow thruster (if fitted): |
0 bhp |
0 Kw |
| 8.15 |
What is brake horse power of stern thruster (if fitted): |
0 bhp |
0 Kw |
| 8.16 |
Does vessel comply with the latest edition of OCIMF 'Recommendations for Equipment Employed in the Mooring of Vessels at Single Point Moorings (SPM)': |
Yes |
| 8.17 |
Is vessel fitted with chain stopper(s): |
Yes |
| 8.18 |
How many chain stopper(s) are fitted: |
2 |
| 8.19 |
State type of chain stopper(s) fitted: |
TONGUE TYPE |
| 8.20 |
Safe Working Load (SWL) of chain stopper(s): |
200 MT |
| 8.21 |
What is the maximum size chain diameter the bow stopper(s) can handle: |
76 mm |
| 8.22 |
Distance between the bow fairlead and chain stopper/bracket: |
3500 mm |
| 8.23 |
Is bow chock and/or fairlead of enclosed type of OCIMF recommended size (600mm x 450mm)? If not, give details of size: |
Yes Not Applicable |
| 8.24 |
Derrick / Crane description (Number, SWL and location): |
Cranes: 2 x 15 Tonnes Port and Starboard |
| 8.25 |
What is maximum outreach of cranes / derricks outboard of the ship's side: |
8.52 m |
| 8.26 |
Does vessel comply with recommendations contained in OCIMF/ICS Ship To Ship Transfer Guide (Petroleum or Liquified Gas, as applicable): |
Yes |
| |
| 9.1 |
What type of fuel is used for main propulsion? |
380 |
| 9.2 |
What type of fuel is used in the generating plant? |
380 |
| 9.3 |
Capacity of bunker tanks - IFO and MDO/MGO: |
3745.1 m3 |
313.2 m3 0 m3 |
| 9.4 |
Is vessel fitted with fixed or controllable pitch propeller(s)? |
Fixed Pitch |
| 9.5 |
P & I Club - Full Style: |
GARD Tel: TBA Email: TBA |
| 9.6 |
P & I Club coverage - pollution liability coverage: |
1000000000 US$ |
| 9.7 |
Date and place of last Port State Control inspection: |
Oct 04, 2012 / Jubilee |
| 9.8 |
Any outstanding deficiencies as reported by any Port State Control: |
No |
| 9.9 |
If yes, provide details: |
N/A |
| 9.10 |
Has vessel been involved in a pollution, grounding, serious casualty or collision incident during the past 12 months? If yes, full description: |
Pollution: No , n/a Grounding: No , N/A Serious casualty: No , N/A Collision: No , N/A |
| 9.11 |
Last three cargoes / charterers / voyages (Last / 2nd Last / 3rd Last): |
Contact owner for details |
| 9.12 |
Date/Place of last SIRE Inspection: |
Feb 01, 2013 / Texas City |
| 9.13 |
Date/Place of last CDI Inspection: |
N/A |
| 9.14 |
Recent Oil company inspections/screenings (To the best of owners knowledge and without guarantee of acceptance for future business)*:
*Blanket "approvals" are no longer given by Oil Majors and ships are accepted for the voyage on a case by case basis. |
Contact owner for details. |